Beijing Leader & Harvest Electric Technologies Co., Ltd.

Variable Frequency Drive

Home » VFD » Technical Data


Technical Data
Model is explained as follows:

Note:
1 Rated output current is □□□A, including 3 digital bits.
2 Rated output voltage: 03-3kV; 03.3-3.3kV; 04.16-4.16kV; 06-6kV; 06.6-6.6kV; 10-10kV; 11-11kV.
3 Control mode: A- asynchronous motor; S-synchronous motor; VA-asynchronous motor vector control; VS- synchronous motor vector control; FVA-asynchronous motor, regenerative drive, vector control; FVS-synchronous motor, regenerative drive, vector control
For example:

3KV series VFD

Model A03/050~ A03/100 A03/100~ A03/175 A03/175 ~A03/220 A03/220~A03/400 A03/220~A03/610
Capacity(kVA) 250~630 630~900 900~1150 1150~2000 2000~3125
Rated output current (A) 50~100 100~175 175~220 220~400 400~610
Motor power (kW) 200~400 400~710 710~900 900~1600 1600~2500
Input frequency 45Hz~55Hz
Rted input voltage 3000V±10%
Input power factor 0.95 (>20%load)
Efficiency 0.96 with rated load
Output frequency 0.5Hz~120Hz
Frequency resolution 0.01Hz
Overload capacity 120% 1 min, 150% immediately
Analogue input 0~10V/4~20mA
Analogue output 0~10V/4~20mA
Acceleration/deceleration time 0.1~3000s
Digital output/input expanded according to requirement
Ambience temperature 0~40℃
Storage/transport temperature -40~70℃
Cooling air cooling
Ambience humidity <90% without condensation
Altitude <1000 m
IP class IP20
Size(mm)(W×H×D) 3300×2480×1200 3900×2480×1200 4900×2480×1200 6000×2580×1200 6000×2580×1300
Weight (kg) 3000 ~ 5000 5000 ~ 7300 7300~9200

6KV series VFD

Model A06/050 A06/050~ A06/080 A06/080~ A06/100 A06/100~ A06/170 A06/170~ A06/220 A06/220~ A06/400 A06/400~ A06/610
Capacity(kVA) ≤500 500~800 800~1000 1000~1750 1750~2250 2250~4000 4000~6250
Rated output current (A) ≤50 50~80 80~100 100~170 170~220 220~400 400~610
Motor power (kW) ≤400 400~630 630~800 800~1400 1400~1800 1800~3250 3250~5000
Input frequency 45Hz~55Hz
Rated input voltage 6000V±10%
Power factor 0.95(>20%load)
Efficiency 0.96with rated load
Output frequency 0.5Hz~120Hz
Frequency resolution 0.01Hz
Overload capacity 120% 1 min, 150% immediately
Analogue input 0~10V/4~20mA
Analogue output 0~10V/4~20mA
Acceleration/deceleration time 0.1~3000s
Digital input/output expanded according to requirement
Ambience temperature 0~40℃
Storage/transport temperature -40~70℃
Cooling air cooling
Ambience humidity <90%,without condensation
Altitude <1000m
IP class IP20
Size(mm)(W×H×D) 3600×2480×1200 3900×2480×1200 4200×2480×1200 5100×2480×1200 5200×2580×1200 6600×2580×1300 8700×2780×1400
Weight (kg) 3500~4000 4000~5000 5000~6000 6000~8000 8000~14000

10KV series VFD

Model A10/080 A10/080~ A10/150 A10/150~ A10/210 A10/210~ A10/400
Capacity(kVA) ≤1250 1250~2500 2500~3500 3500~6250
Rated output current (A) ≤80Rated output current (A) 80~150 150~210 210~400
Motor power(kW) ≤1000 1000~2000 2000~2800 2800~5000
Input frequency 45Hz~55Hz
Rated input voltage 10000V±10%
Power factor 0.95(>20%load)
Efficiency 0.96with rated load
Output frequency 0.5Hz~120Hz
Frequency resolution 0.01Hz
Overload capacity 120% 1 min, 150% immediately
Analogue input 0~10V/4~20mA
Analogue output 0~10V/4~20mA
Acceleration/deceleration time 0.1~3000s
Digital input/output expanded according to requirement
Ambience temperature 0~40℃
Storage/transport temperature -40~70℃
Cooling air cooling
Ambience humidity <90%,without condensation
Altitude <1000m
IP class IP20
Size(mm)(W×H×D) 4500×2480×1200 5700×2480×1200 6800×2580×1300 10600×2580×1300
Weight(kg) 3500~6000 6000~8000 8000~15000 15000~19000
Variable Frequency Drive
  • A VFD HARSVERT-A series VFD is a masterpiece of outstanding performance and high reliability, which is widely used for the energy-saving application of the normal motors of fans, pumps ...
  • VS VFD Vector control for the speed-adjustment of synchronous motor;
    Start ability for starting the synchronous motor with load;
    The response time of dynamic torque: less ...
  • FVS VFD PWM rectifier technology. Energy can flow bi-directionally between power grid and the motor;
    Vector control for synchronous motor;
    Strong start up with load in ...
  • FVA VFD Auto re-start after the recovery of main medium voltage;
    Fly-start at any rotating speed;
    Bypass the faulty power cell automatically( OPTIONAL FUNCTION) ...